We distribute this product only in the Czech Republic and Slovakia.

PulseCheck

APE 's PulseCheck NX is a new generation of instruments for measuring short pulses ranging from 5 fs to 500 ps. With a wide range of detector types and optical kits, PulseCheck NX offers a flexible and modular solution for a wide range of professional applications, whether it is pulse measurement at low pulse energies or laser measurement with high peak power. This is in the wavelength range from UV to IR, from 200 nm to 12 μm.

Key Features

  • Interchangeable optics kit for wavelength coverage from 200 nm to 12 μm
  • Wide range of sensitivity levels covered by PMT, PD, and TPA
  • High temporal resolution with sampling resolution up to 50 attoseconds
  • Switching between collinear (interferometric) autocorrelation and non-collinear (intensity) autocorrelation
  • Integrated controls for data acquisition, data logging, and fast FPGA data processing
  • Software crystal wavelength tuning (phase matching)
  • Fully compatible with DIN 58175-2:2021-04 (pulse measurement)
  • NX-Software, USB, Ethernet
  • PulseCheck offers easy operability and plug & play compatibility via USB
  • TCP/IP remote control with standardized command set for easy programming
  • Optional: FROG for complete pulse characterization
Martin Klečka
Expert advisor

Ing. Martin Klečka

+420 607 014 278

klecka@optixs.cz

Send inquiry

OptiXs care

  • We will expertly consult your planned application
  • Our team is able to integrate the product into a larger system
  • We ensure fast delivery of spare parts and local service
What else we can help with

Parameters

Max. power consumption, pulse energy

Model NX 50 NX 150 SM 2000
Pulse width 5 fs ...15 fs 10 fs ... 40 ps 20 fs ... 500 ps
Wavelength range

200 nm ... 12 µm

*depending on the optics set

Recommended repetition rate

PD, TPA: >10 Hz, only for UV:

PMT: >250 kHz

Sensitivity* (typical)

1 W2 ... 10-6 W2

*depending on the optics set

Max. power, pulsed energy

0.5 W for quasi-cw laser

5 µJ for kHz laser

Input beam polarization

Linear horizontal

(optional equipment - polarization rotator)

Input beam Free beam diameter up to 6 mm or optional fibre optic coupling (FC/PC or FC/APC)>

*Measured sensitivity including optics set, defined as average power multiplied by peak power of incident pulses: PAV * Ppeak.